Pax Calima® Automatic functions and settings via app
Default setting:
Pax Calima is programmed to cope with the vast majority of installations.
The fan works continuously with a flow of 30m³/h.
When the fan senses a somebody in the room it increases the flow to 60m³/h.
If the humidity rises rapidly for example when the shower is on, the fan goes up to maximum flow at 95m³/h.
When the fan senses the moisture level has returned to normal it reverts to the basic flow of 30m³/h.
If other settings or functions are desired download Pax app that can be downloaded from the and Google Play.
Technical requirements for Pax app:
Android OS 4.3 or later with support for Bluetooth 4th.
Fault indication:
Red LED on the fan indicates power failure when the calendar function has been activated. Recovered by the app synch with the fan.
Learn more about all the possibilities with our app at www.pax.se
Activate the app:
You have to have a code to activate the app, the code is unique for each fan. Enter the code or scan through the phone. Your own unique code is on the back of the manual.
Easy use - app control:
When the fan is supplied it is preset to be an automatic bathroom fan with constant basic flow, humidity and light detectors activated.
The app control via Bluetooth gives you the functionality of five fans in one. Via Pax smart app you can set up Calima for various functions and environments. You can easily set up Calima to be a heat transferrer, function as a backdraught shutter, or to be activated with a switch. Via the app you can also use a simple calender function where you can activate various functions depending on weekdays or weekends.
Profiles in app:
Electrical connection 100-240VAC
Calima auto:
100-240VAC 50 / 60Hz
Continuous basic ventilation, automatic boost at elevated moisture levels, and the influence of light change.
Calima switches operated on/off :
(Can be combined with backdraft shutter)
100-240VAC 50 / 60Hz
Must be selected via Pax App.
Start / stop via manual switch L.
Calima moisture controlled:
(Can be combined with backdraft shutter)
100-240VAC 50 / 60Hz
Must be selected via Pax App.
Basic setting, automatic start / stop
changes in moisture levels.
Calima Heat Distributor:
100-240VAC 50/60Hz
Must be selected via Pax App.
Basic settings, starting at 25 ° C, stop at 22 ° C.
Calima switches operated on/off, with overrun:
(Can be combined with backdraft shutter)
100-240VAC 50 / 60Hz
Must be selected via Pax App.
Start / stop via manual switch T.
Electrical connection 12VDC
Calima auto:
12VDC (switch C always)
Continuous basic ventilation, automatic forcing at elevated moisture levels, and the influence of light change.
Calima switches operated on/off:
(Can be combined with backdraft shutters)
12VDC
Must be selected via Pax App.
Start / stop via manual switch C.
Calima moisture controlled:
(Can be combined with backdraft shutters)
12VDC (switch C always)
Must be selected via Pax App.
Basic setting, automatic start / stop
changes in moisture levels.
Calima Heat Distributor:
12VDC (switch C always)
Must be selected via Pax App.
Basic settings, starting at 25 ° C, stop at 22 ° C.
Adjustments/settings via app:
Flow adjustments
Calendar function
Forced ventilation
After run
Start delay
Light Sensitivity
Ažurirano dana