1. PROTECTION
- protective schemes
(i)core balanced protective schemes.
(ii) merz-price protective schemes.
(iii) pilot
(iv) pilot-less.
- types of relay systems
(i) permanent magnet moving coil.
(i) balanced beam
(ii) induction type carrying relay
(iv) the distance relay
(v)non-directional relay
(vi)solid state relay.

-types of unit protection

(i)generator protection
(ii) transformer protection
(iii) feeder protection

- non-unit protection
(i)directional current protection
(ii) distance protection
(iii) gradient time protection

2.OVERHEAD LINE CONSTRUCTION
- conductor/mechanical vibration

(i) swinging
(ii)dancing
(iii) jumping
(iv) high frequency vibration

- sag and tension
(i)ca-ternary method

-corona phenomenon
(i)disruptive
(ii)visible
(iii)critical
(iv)power loss

- operation of synchronous phase modifies
(i)lagging and leading
(ii)volt drop compensation


3. OVERHEAD LINE TRANSMISSION
- classification of transmission lines
(i)short, medium and long lines
- causes of surges in transmission line
(i)direct and indirect lighting stroke
(ii)open circuited lines
(iii)short circuited lines
(iv)an arching ground faults
--phenomenon surges explanation in transmission line
(i)surge velocity
(ii)surge impedance
(iii)open circuited and short circuited lines
--protection of transmission line against surges
(i)overhead earth wire
(ii)horn gaps
(iii)silicon and zinc oxides surge diverts
(iv)Peterson coil

4.UNSYMMETRICAL FAULTS
--types of power line faults
(i)single phase to ground fault (L - G)
(ii)3-phase faults (L - L -L)
(iii)double line to ground fault (L - L - G)
--description of symmetrical components
(i)positive, negative and zero sequence vector
(ii)Impendence connection matrices for fault
(iii)equivalent circuit for unsymmetrical fault
--operation of equivalent circuit and phase sequence matrix

5. POWER SYSTEM STABILITY
--synchronous generator stability
(i)power transfer regulation
(ii)derivation of equal area of criterion
(iii)change of load
(iv)change in transfer reluctance due to switches
(v)change in transfer reactance due to faults

--derivation of swing equation
--swing cap
--methods of improving both transients and steady state stability
Aktualisiert am
29.09.2024

Datensicherheit

Was die Sicherheit angeht, solltest du als Erstes verstehen, wie Entwickler deine Daten erheben und weitergeben. Die Datenschutz- und Sicherheitspraktiken können je nach deiner Verwendung, deiner Region und deinem Alter variieren. Diese Informationen wurden vom Entwickler zur Verfügung gestellt und können jederzeit von ihm geändert werden.
Keine Daten werden mit Drittunternehmen oder -organisationen geteilt
Diese App kann die folgenden Datentypen erheben
Standort, Nachrichten und 2 andere
Daten werden bei der Übertragung verschlüsselt
Daten können nicht gelöscht werden

Neuerungen

ELECTRICAL POWER SYSTEMS NOTES