Modbus Monitor Advanced

Ilova ichida xaridlar
1 ming+
Yuklanmalar
Yoshga oid cheklov
Hamma uchun
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot
Skrinshot

Bu ilova haqida

Learn Modbus with full protocol stacks, or get all data from your remote Modbus RTU devices by defining your full modbus map, or use your mobile devcie to simulate Modbus devices or sensors.

This Modbus App has three Apps in one:
(1) Modbus Client (Master)
(2) Modbus Server (Slave)
(3) Modbus TCP Sensors Server

Four Interfaces:
(1) Bluetooth SPP & BLE
(2) Ethernet
(3) Wi-Fi
(4) RS232/485 USB Serial ports via USB OTG

Eight Protocols to choose from:
(1) Modbus TCP
(2) Enron/Daniels TCP
(3) Modbus RTU over TCP
(4) Modbus UDP
(5) Modbus RTU over UDP
(6) Modbus TCP Slave/Server
(7) Modbus RTU
(8) Modbus Serial ASCII

Push data to cloud:
> MQTT
> Google Sheets
> ThinkSpeak

Sensor Server:
Explore Sensor Server: Remotely monitor mobile device's sensors using Modbus Protocols

Import/Export:
Import in CSV format. Export data to CSV format every second, minute, or hour. Export configuration data via email or log to ThinkSpeak or Google Sheets Cloud platforms

About Modbus Support
(1) Modbus Functions: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto

(2) Simple 6 digit Input Modbus Address input (4x, 3x, 1x, 0x)

(3) Data Conversion: Unsigned, Signed, Hex, Binary, Long, Double, Float, String, BCD formats, Unix Epoch Time, PLC Scaling (Bipolar/Unipolar Analog ADC value conversion)

(4) Convert Modbus Integer Values to Text (Coded Message or Status Converter)

(5) Push to write pre-set value

Pro-Turning Options

Interval, Inter-Packet Delay, Link-Timeout, Actual RX/TX Counts

Bluetooth Requirements:

(1) Your device must have Bluetooth Radio that supports SPP profile (RFCOMM Secure or Insecure)
(2) See "ModbusMonitor.com" or email help@modbusmonitor.com for help
(3) See below for hardware requirements

USB-OTG Serial Ports Requirements:
(1) Your device must be Android version 3.2 or newer
(2) Your device must support USB Host or OTG interface
(3) Your USB-to-Serial Port dongle must contain one of following chipsets: >FTDI [FT230X, FT231X, FT234XD, FT232R, or FT232H], Prolific [PL2303HXD, PL2303EA, or PL2303RA], SiLab [CP210x], QinHeng CH34x
(4) RS485: Tested with "no echo" setting turned ON.

Feedback
www.ModbusMonitor.com contains an online form in the "Feeback" section for those interested in providing constructive feedback or feature requests.
Oxirgi yangilanish
29-okt, 2023

Maʼlumotlar xavfsizligi

Xavfsizlik — dastur ishlab chiquvchilar maʼlumotlaringizni qanday jamlashi va ulashishini tushinishdan boshlanadi. Maʼlumotlar maxfiyligi va xavfsizlik amaliyotlari ilovadan foydalanish, hudud va yoshga qarab farq qilishi mumkin. Bu axborot dastur ishlab chiquvchi tomonidan taqdim etilgan va keyinchalik yangilanishi mumkin.
Tashqi hamkorlarga hech qanday axborot ulashilmagan
Dastur ishlab chiquvchilar axborot ulashilishini qanday aytishi haqida batafsil
Hech qanday maʼlumot jamlanmagan
Dastur ishlab chiquvchilar axborot jamlanishini qanday aytishi haqida batafsil

Nima yangiliklar

Updated to comply with Android Policy