Funda i-Modbus ngezitaki zephrothokholi ezigcwele, noma thola yonke idatha kumadivayisi akho akude e-Modbus RTU ngokuchaza imephu yakho ye-modbus egcwele, noma usebenzise i-devcie yakho yeselula ukuze ulingise amadivayisi we-Modbus noma izinzwa.
Lolu hlelo lokusebenza lwe-Modbus lunezinhlelo zokusebenza ezintathu kokukodwa:
(1) Iklayenti le-Modbus (Inkosi)
(2) Iseva ye-Modbus (Isigqila)
(3) Iseva yezinzwa ze-Modbus TCP
Izixhumi ezibonakalayo ezine:
(1) I-Bluetooth SPP & BLE
(2) I-Ethernet
(3) I-Wi-Fi
(4) RS232/485 USB Serial izimbobo nge-USB OTG
Amaphrothokholi ayisishiyagalombili ongakhetha kuwo:
(1) I-Modbus TCP
(2) Enron/Daniels TCP
(3) I-Modbus RTU phezu kwe-TCP
(4) I-Modbus UDP
(5) I-Modbus RTU ngaphezu kwe-UDP
(6) I-Modbus TCP Slave/Iseva
(7) Modbus RTU
(8) I-Modbus Serial ASCII
Phusha idatha kumafu:
> MQTT
> Google AmaSpredishithi
> ThinkSpeak
Iseva yenzwa:
Hlola Iseva Yezinzwa: Qapha ukude izinzwa zedivayisi yeselula usebenzisa i-Modbus Protocols
Ngenisa/Thekelisa:
Ngenisa ngefomethi ye-CSV. Thumela idatha kufomethi ye-CSV njalo ngesekhondi, iminithi, noma ihora. Khipha idatha yokumisa nge-imeyili noma ungene ku-ThinkSpeak noma izinkundla ze-Google Amashidi Cloud
Mayelana ne-Modbus Support
(1) Imisebenzi ye-Modbus: FC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, Write Auto
(2) Okokufaka kwekheli le-Modbus okulula okuyizinhlamvu ezingu-6 (4x, 3x, 1x, 0x)
(3) Ukuguqulwa Kwedatha: Okungasayiniwe, Kusayinwe, i-Hex, kanambambili, Okude, Okuphindwe kabili, Ukuntanta, Izintambo, amafomethi we-BCD, Isikhathi se-Unix Epoch, Ukukala kwe-PLC (ukuguqulwa kwenani le-Bipolar/Unipolar Analog ADC)
(4) Guqula Amanani Aphelele e-Modbus abe Umbhalo (Umlayezo Onekhodi noma Isiguquli Sesimo)
(5) Phusha ukuze ubhale inani esethiwe
Izinketho ze-Pro-Turning
Isikhawu, I-Inter-Packet Ukubambezeleka, I-Link-Timeout, Izibalo Zangempela ze-RX/TX
Izidingo ze-Bluetooth:
(1) Idivayisi yakho kufanele ibe ne-Bluetooth Radio esekela iphrofayela ye-SPP (RFCOMM Secure or Insecure)
(2) Bona okuthi "ModbusMonitor.com" noma uthumele i-imeyili ku-help@modbusmonitor.com ukuze uthole usizo
(3) Bheka ngezansi ngezidingo zezingxenyekazi zekhompuyutha
Izidingo zezimbobo ze-USB-OTG:
(1) Idivayisi yakho kufanele ibe yinguqulo ye-Android 3.2 noma entsha
(2) Idivayisi yakho kufanele isekele i-USB Host noma i-OTG interface
(3) Imbobo ye-dongle yakho ye-USB-to-Serial kufanele iqukathe okukodwa kwama-chipset alandelayo: >FTDI [FT230X, FT231X, FT234XD, FT232R, noma FT232H], Prolific [PL2303HXD, PL2303EA, noma PL2303RA, FT231X, FT234XD, FT232R, noma FT232H], Prolific [PL2303HXD, PL2303EA, noma PL2303RA, 2303RA, 2303RA, Q4xb0]
(4) RS485: Ihlolwe ngesilungiselelo esithi "no echo" IVULIWE.
Impendulo
I-www.ModbusMonitor.com iqukethe ifomu eliku-inthanethi esigabeni esithi "Impendulo" yalabo abathanda ukunikeza impendulo eyakhayo noma izicelo zesici.
Kubuyekezwe ngo-
Okt 29, 2023