Voltage Drop sizes wire by voltage drop. It works out the voltage lost along a run of wire, and the wire size, run or load that keeps it within your limit. It works every figure from the size of the wire and the physics of copper and aluminium, and shows every step of the arithmetic so you can check it.
Four ways to work
• Voltage drop: the volts and percent dropped, the voltage left at the load and the power lost in the wires, with the smallest size, longest run and most current that would keep within your limit
• Wire size: the smallest size that keeps the drop within your limit, and what the size below it would drop
• Longest run: how far a size can go before the drop passes your limit, rounded down so the figure shown always keeps within it
• Most current: how much load a size can take over a run before the drop passes your limit
Circuits and wire
• DC, single-phase AC and three-phase AC (line to line), with the factor of 2 or √3 shown
• Copper or aluminium, one set or up to ten sets in parallel
• AWG 18 to 4/0 and kcmil 250 to 1000, or metric sizes from 1.5 to 400 mm²
• Lengths in feet or metres, one way from the source to the load
• Conductor temperature you can set: 75 °C unless you change it
• A limit you choose, such as 2, 3 or 5%
• Every size side by side for your circuit, with the ones within your limit marked
Worked from the physics, not copied tables
• Each conductor's resistance comes from its cross-section (the AWG diameter formula, the kcmil or the mm²), the resistivity of copper or aluminium at 20 °C, their temperature coefficients and a stated allowance for stranding
• For AWG and kcmil sizes it agrees with published US conductor tables within about 1%
• Metric sizes are worked from their nominal area, and the app says how that compares with the international conductor standard
AC reactance, if you want it
• Turn it on for AC to include each conductor's reactance, worked out from the spacing between conductors, and the skin effect, at the power factor you enter, at 60 or 50 Hz
• Left off, the result is the resistive drop, and the app says plainly that large conductors on AC drop more
Every step shown
• From the wire's area to the answer, with your numbers in, so you or an inspector can check it with a calculator
• Share any result as plain text
Made for the job
• Works offline. No account, no ads, no subscription. One price, once.
• Several circuits saved on your phone, with examples to start from
• Light and dark screens
• Nothing is collected: the app has no internet access
Safety: Voltage Drop is a calculating aid, not the electrical code, and not a substitute for the inspector or a qualified electrician. It works out voltage drop only: check the wire's ampacity, its protection and the rest of the circuit against your local code. Results are estimates that depend on what you enter. Work on circuits only if you are qualified to, with the power off and locked out.
Questions or a number that looks wrong? Email hammercreativestudios@gmail.com.
Voltage drop calculator for DC, single and three phase, copper or aluminum.