Oxyg'App

100+
Downloads
Content rating
Everyone
Screenshot image
Screenshot image
Screenshot image

About this app

Oxygen management should rely on oxygenation targets, with minimal and maximal boundaries to avoid both hypoxemia and hyperoxemia. Oxygen titration using targets based on arterial saturation (SaO2) are not feasible due to discontinuous measurements of this parameter. The oxygen support must be titrated based on SpO2 that allows continuous measurements of patient oxygenation, even though this technology has limitations and needs improvement. We may hope for a major technological evolution as the main working principles of this technology, which are more than 50 years old, have not changed appreciably38. Waiting for this improvement in pulse oximetry technology, clinicians should tread carefully and apply algorithms to correct for these deficiencies. Whatever the clinician thinks is the appropriate oxygenation target, this "optimal SaO2" target needs to be corrected when utilizing the SpO2 for the titration based on skin pigmentation and oximeter brand. It has become increasingly apparent that the SpO2 target cannot simply be the SaO2 target!
To facilitate the quest of the optimal SpO2 targets and to promote a more homogeneous management of patients’ oxygenation regardless of skin pigmentation or monitoring device of oxygenation there are several potential solutions. We believe that one SpO2 target does not fit all patients and that further clinical trials and clinical guidelines should use corrected SpO2 targets rather than universal targets for all patients. Consequently, clinicians should first define a SaO2 target relative to the patient under respiratory support and then apply corrections for the mean bias related to the skin pigmentation and to the oximeter used to get the corrected SpO2 (Figure 3).
The COVID-19 pandemic has served to remind clinicians of the impact of skin pigment on oximeter accuracy. Old lessons learned anew. Device accuracy is both different and variable between brands. And while pulse oximetry is ubiquitous to virtually every healthcare delivery system, the simplicity of oximetry use belies a need for a more nuanced interpretation of SpO2 to avoid untoward consequences.

oxygapp
Updated on
Nov 21, 2023

Data safety

Safety starts with understanding how developers collect and share your data. Data privacy and security practices may vary based on your use, region, and age. The developer provided this information and may update it over time.
No data shared with third parties
Learn more about how developers declare sharing
This app may collect these data types
Personal info
Data is encrypted in transit
Data can’t be deleted

What’s new

Add warning about the educational intent of the app

App support

About the developer
Institut Universitaire de Cardiologie et de Pneumologie de Québec - Université Laval
comptabilite@effenti.ca
2725 ch Sainte-Foy Québec, QC G1V 4G5 Canada
+1 418-952-5778

More by IUCPQ