Method Validation Calculator

Contains adsIn-app purchases
Content rating
Everyone
0+
Downloads
Content rating
Everyone
In-App Purchases
Learn more
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image

About this app

Method Validation replaces the spreadsheets a pharmaceutical QC laboratory uses to validate
an analytical method. Enter the raw data — weights, volumes, peak areas, absorbances — and
the app computes every validation parameter, applies the acceptance criteria and gives a
three-state verdict for each one: PASS, FAIL or INSUFFICIENT DATA.

WORKFLOWS
• HPLC / GC assay according to ICH Q2(R2): system suitability (RSD, tailing, plate count),
linearity and working range (slope, intercept, r, R², residuals, response factor), repeatability
on three matrices, accuracy with 9 spiked samples and 95 % confidence interval, intermediate
precision (day 2, F-test), Grubbs outlier check, measurement uncertainty (top-down).
• Heavy metals by GF-AAS / ICP according to Ph. Eur. 2.4.27: calibration curve at the start and
end of the run (slope drift), reagent blanks with LOD / LOQ, standard addition recovery on
several matrices, repeatability (independent flasks), intermediate precision by ISO 5725
ANOVA, drift trend and a full top-down uncertainty budget.
• Generic profile for ICH / USP <1225> / ASEAN / ISO 17025 methods: assay, SST, accuracy,
precision, linearity with LOD / LOQ from the calibration line.

CORRECT BY CONSTRUCTION
Every formula was verified cell by cell against the laboratory's original validated workbooks
(≈ 600 cells, relative tolerance 1e-9). Excel semantics are kept where they matter (sample SD,
TINV / FINV, regression statistics). Blank or zero cells count as "not entered", never as data.

BUILT FOR THE BENCH
• Column quick-entry (Enter → next row), paste a whole column from Excel, or import a column
straight from the instrument's CSV / TSV export (Empower, Chromeleon, LabSolutions…).
• Vietnamese and English number formats (1.234,56 and 1,234.56) are both understood.
• Live verdict bar while you type; KPI dashboard; formula trace for every result.
• Undo / redo and a full audit trail of every changed cell (21 CFR Part 11 style).
• Record lifecycle Draft → Reviewed → Approved with optional PIN e-signature.

REPORTS
• PDF report with your laboratory name, logo, form code, page numbers, sign-off table and an
optional raw-data appendix — Vietnamese fonts embedded.
• Excel workbook (.xlsx) with one sheet per parameter and yellow input cells, plus CSV.
• Project bundle (.mvproj) for backup and transfer between devices.
• Share, open, or save any export to Downloads / Google Drive.

ORGANISE
Search, filter and sort projects; tags; duplicate a project; save the settings and criteria of a
project as a template and start the next validation from it; archive finished work.

PRIVACY
All data stays on your device — there is no server and no account. The app is free with ads;
an optional Pro upgrade (lifetime or yearly) removes ads and unlocks lab branding, Excel export,
templates, PIN sign-off and the advanced tools. Full English and Vietnamese interface — including
every data-entry tab, the conclusion and the PDF/CSV/Excel reports — following the device
language or the setting in the app.

Disclaimer: this app is a calculation aid. The laboratory remains responsible for reviewing the
inputs, the acceptance criteria and the final conclusion.

**What's new (500):**
1.3.1 — Full English interface and reports (data-entry tabs, conclusion, PDF/CSV/Excel), follows
the device language. Free + Pro model: lifetime or yearly Pro removes ads and unlocks lab
branding, Excel export, templates, PIN sign-off and advanced tools. Extended HPLC parameters
(specificity, stability, LOD/LOQ, robustness), bottom-up uncertainty budget, titration / Karl
Fischer module, multi-element panel, two-lab comparison, SST control chart, dissolution f2,
ICH Q3D limits.
Analytical method validation: HPLC ICH Q2(R2), AAS Ph. Eur. 2.4.27, USP/ISO
Updated on
Oct 1, 2026
Featured stories

Data safety

Safety starts with understanding how developers collect and share your data. Data privacy and security practices may vary based on your use, region, and age. The developer provided this information and may update it over time.
  • No data shared with third parties
    Learn more about how developers declare sharing
  • This app may collect these data types
    Location and Device or other IDs
  • Data is encrypted in transit
  • You can request that data be deleted

What’s new

fix crash bug
Content rating
Everyone
In-App Purchases
Learn more

App support

About the developer
VÕ MINH THẮNG
minhthang0792@gmail.com
33, KP Cầu Xéo, Hậu Thành Cái Bè Tiền Giang Vietnam

More by MT.Co