LungScore Pro: Lung Ultrasound

In-app purchases
Content rating
Everyone
0+
Downloads
Content rating
Everyone
In-App Purchases
Learn more
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image
Screenshot image

About this app

LungScore Pro is a bedside lung ultrasound (LUS) aeration score calculator for clinicians trained in lung ultrasound: neonatologists, paediatric and adult intensivists, emergency physicians and pulmonologists. Score each zone 0–3 with one thumb while the other hand holds the probe; the LUS Aeration Score, the regional subtotals and the published reference ranges update as you tap.

FIVE PROTOCOLS, ONE GRID
• Classic neonatal LUS (Brat score): 6 zones, total 0–18 (Brat et al., JAMA Pediatrics 2015)
• Extended neonatal LUS (eLUS): 10 zones, total 0–30 (Loi et al. 2021)
• Paediatric / PICU LUS: 12 zones, total 0–36 (Jaworska et al. 2020)
• Adult 12-region LUS: 12 regions, total 0–36 (Bouhemad 2011, Soummer 2012, Mongodi 2021)
• Adult 14-area LUS: 14 areas (Soldati 2020). Soldati proposed no total, so the app shows the 0–42 sum as plain arithmetic and applies no cut-offs to it.

BUILT FOR THE BEDSIDE
• Tap a zone to cycle 0 → 1 → 2 → 3; long-press to clear it
• No login and no patient registration: the app opens on the scoring grid
• The 0–3 grading rubric (A-lines, separate B-lines, coalescent B-lines, consolidation) is one tap away, following the ESICM–ESPNIC 2025 consensus wording
• Pleural findings per side (effusion, absent lung sliding, irregular pleural line, small subpleural consolidation) are recorded without changing the score
• Oxygenation indices from the values you enter: SpO₂/FiO₂, PaO₂/FiO₂, oxygenation index, oxygen saturation index and the ROX index

CITED REFERENCE RANGES, NOT INSTRUCTIONS
Below the score, interpretation cards show where the total or the relevant subtotal sits against cut-offs published in peer-reviewed studies, guidelines and consensus statements, each with its population, timing, accuracy and citation. Neonatal cards show the cited surfactant cut-offs (Brat 2015, De Martino 2018) next to the score rather than one number; adult 12-region cards include the Soummer 2012 weaning thresholds. Cards present information for consideration; they never tell you what to do. The full reference list is in the app.

DOCUMENTATION
• Copy a one-line summary for the clinical note, for example "Classic neonatal LUS: 10/18 [R: 2,2,1 | L: 2,2,1]", or the full plain-text summary with anterior, lateral and posterior subtotals
• Pro: unlimited saved scans, serial trends (Delta LUS) per bed or study ID, a one-page visual PDF report with a lung map and a verification QR code, and cohort export (CSV and Excel) for research registries

FREE AND PRO
Scoring never needs Pro. Free: every protocol, live totals and subtotals, cited reference ranges, the rubric, oxygenation indices, the copied summaries and the last 3 saved scans. Pro is a monthly or annual subscription (the annual plan starts with a 14-day free trial), a trainee annual plan, or a one-time lifetime purchase. Subscriptions renew automatically unless cancelled at least 24 hours before the end of the current period; manage them in your store account settings.

PRIVACY
No accounts, no analytics, scans encrypted on the device. The app asks for no patient identifiers: labels, study IDs and notes are free text you choose, so never enter names, dates of birth or record numbers.

CLINICAL DISCLAIMER
LungScore Pro is a clinical reference and documentation calculator. It sums clinician-entered per-zone aeration scores and displays published cut-offs with their source so you can review the basis independently. It does not analyse images, does not make diagnoses and does not recommend treatment; decisions remain with the treating clinician. LungScore Pro is not CE-marked, UKCA-marked or cleared by the US FDA.

Privacy policy: https://lungscorepro.com/privacy/
Terms of use: https://lungscorepro.com/terms/
Support: https://lungscorepro.com/support/
LUS aeration score calculator: Brat score, neonatal, PICU and adult ICU POCUS
Updated on
Nov 2, 2026

Data safety

Safety starts with understanding how developers collect and share your data. Data privacy and security practices may vary based on your use, region, and age. The developer provided this information and may update it over time.
  • No data shared with third parties
    Learn more about how developers declare sharing
  • No data collected
    Learn more about how developers declare collection

What’s new

First release of LungScore Pro: five LUS protocols, cited reference ranges, oxygenation indices, saved scans, serial trends, PDF reports and cohort export.
Content rating
Everyone
In-App Purchases
Learn more

App support

About the developer
MYBABYNUTRI SOLE SHAREHOLDER CO. P.C.
info@mybabynutri.com
Thermi 57001 Greece
+30 694 161 7403

More by myBabyNUTRI